HH6 series of small power relays have a small size, light weight, high reliability and large capacity switch, long life, high temperature, moisture-resistant features for the exchange of 50Hz or 60Hz, voltage to 240V, DC voltage to 110V, current 15A to the circuit for air-conditioning, automotive and industrial automation control devices, such as signaling for and implementation of the components. As well as products in line with the GB14048 standard IEC255, IEC947 and Japan JIS standard.
Model |
HH6 |
Classification |
Small power relay |
Standard varieties |
-Type, with light, with surge suppression |
Contact form |
1c,2c,3c,4c |
Rated load |
15A/10A 220VAC/24VDC (resistive load Res.load) |
Xinhua life (AC-12) |
2×10 5 |
Installation |
Plug-and PCB-type flange |
Characteristics |
and large-capacity, long life, a variety of ways to install the product in line with international standards |
Product Certification |
UL (HH62) CE TUV CCC |
Standard varieties
Type |
Relay Model |
The number of contacts |
Rated voltage (Us) |
Pluggable |
PCB-Welding |
Flanged |
Screw - |
-Type |
HH61P |
HH61B |
HH61S |
—— |
1 conversion |
AC6,12,24,48,110,220V 50/60Hz DC6,12,24,48,110V |
HH62P |
HH62B |
HH62S |
HH62E |
2 conversion |
HH63P |
HH63B |
—— -- |
—— |
3 conversion |
HH64P |
HH64B |
HH64S |
—— |
4 conversion |
Lead indicator for |
HH61P-L |
HH61B-L |
—— |
—— |
1 conversion |
AC6,12,24,48,110,220V 50/60Hz 50/60Hz DC24,48,110V |
HH62P-L |
HH62B-L |
—— |
HH62E-L |
2 conversion |
HH63P-L |
HH63B-L |
—— |
—— |
3 conversion |
HH64P-L |
HH64B-L |
—— |
—— |
4 conversion |
With surge suppression circuit |
HH61P-F |
HH61P-F |
HH61S-F |
—— |
1 conversion |
DC24, 48,110 V |
HH62P-F |
HH62P-F |
HH62S-F |
HH62E-F |
2 conversion |
HH63P-F |
HH63P-F |
—— |
—— |
3 conversion |
DC12, 24,48,110 V |
HH64P-F |
HH64P-F |
HH64S-F |
—— |
4 conversion |
With surge suppression circuit and light action |
HH61P-FL |
HH61P-FL |
—— |
—— |
1 conversion |
DC24, 48,110 V |
HH62P-FL |
HH62P-FL |
—— |
HH62E-FL HH62E-FL |
2 conversion |
HH63P-FL |
HH63P-FL |
—— |
—— |
3 conversion |
DC24, 48,110 V |
HH64P-FL |
HH64P-FL |
—— |
—— |
4 conversion |
Technical Data
Model |
HH61 |
HH62 |
HH63 |
HH64 |
Rated insulation voltage |
250V |
Voltage action |
AC: <80% Us |
AC: <80% Us |
DC: <75% Us |
DC: <80% Us |
Release voltage |
AC:> 30% Us DC:> 10% Us |
The largest electricity voltage |
110% Us |
Time moves |
<20ms |
Release time |
<20ms |
Current agreement fever |
15A |
10A |
Rated load |
AC-12 AC-15 DC-12 DC-13 |
220V3A 220V3A 110V0.3A 110V0.3A |
Rated power |
AC: 1.8VA DC: 1.2W |
AC 2.5VA DC 1.8W |
AC 3VA DC 1.8W |
Contact resistance |
<50m Ω (initial value) |
Insulation resistance |
> 100M Ω |
Switching frequency |
≤ 30cpm |
Pressure Frequency |
Contact between the same group: AC1000V 1min Electrical circuit between: AC2000V 1min |
Ambient temperature |
-25 To +55 ℃ |
Vibration |
10-50Hz 1.0mm Vibration stability |
Impact |
200m/s 2 Impact on stability |
Mechanical life |
5×10 7 |
Xinhua Life |
2×10 5 |
|